SINEAX P530
Measuring transducer for active power
1 Operating Instructions in three languages: German, French and English
- Measuring method: TDM method
- Measurement inputs: sinusoidal nominal input current (1 or 5 A) and nominal input voltage (100 to 690 V)
- Nominal input frequency: 50 Hz
- Measuring range: 0 to 4 kW
- Measurement output: unipolar, bipolar or live-zero output quantities
- Power supply: integrated AC-DC power pack with large tolerance range for universal use
- Maritime product features (formerly GL, Germanischer Lloyd) / suitable for use on ocean-going vessels
- Housings – top-hat rail mounting
- P13/70 housing for single-phase alternating current
- P18/105 housing for 3-phase current
- CSA certificate , German Lloyd approval
Measuring transducer for the conversion of active power in single phase alternating current or 3-phase systems with balanced or unbalanced load.
A load-independent direct current or direct voltage is used as an output signal, which is proportional to the measured active power value.